It demonstrates your integrity and likely why you're successful in business. Hi, first off, thanks for providing this information. If you're receiving a bF or Check 103 error, and you have an AlarmNet Communicator, then further troubleshooting will be required.ĭid you find this answer useful? We offer alarm monitoring as low as $10 / month Click Here to Learn More If your panel is a version 7 or higher, after entering you'll need to press the key twice. On older panels, you should hear three beeps. If you're unsure of the installer code, you can use the backdoor method to access programming. You will see 20 (fixed keypad) or Installer Code 20 (alpha keypad). Enter the Installer Code (default is 4112) + +. If you are receiving a bF (backup failure, displayed on a fixed keypad) or a Check 103, LngRng Radio (displayed on a alpha keypad), and you do not have an AlarmNet communicator, you simply need to disable the communicator through programming.Ĭomplete the following steps to disable the AlarmNet communicator in a Vista P-Series Panel: The combination of these settings, plus the fact that all central station phone number information has been removed, should prevent an FC or Comm Fail message from ever being displayed again. These dynamic signaling settings instruct the panel to attempt to send signals via the AlarmNet device first and allow it as much time as possible to get an acknowledgement. You should either see 20 (fixed keypad) or Installer Code 20 (alpha keypad). To program the Vista P-Series Systems to communicate via an AlarmNet device, and to never attempt to communicate via the dialer, perform the following functions: Because the AlarmNet communicator receives all the signals that it's meant to send via the dialer queue, you cannot just simply shut it down. This switch may have been prompted by the removal of the phone line or a switch to a VoIP phone line, which is not reliable for alarm communication. This could be caused by the fact that the programming for the panel tells it to communicate in this way, but there is no actual phone line to allow it to do so.Ĭomm Failure is often seen on Vista Panels that previously used a phone line to communicate but now use an AlarmNet communicator instead. This message indicates that the alarm panel has attempted to communicate via the built-in dialer, and it failed to receive an acknowledgement that the signal was understood. If a communicator exists, this may indicate troubleshooting is needed.įC means Failed to Communicate (FC is the message shown on a fixed English keypad, like the 6150) or Comm Fail (shown on an alpha keypad, like the 6160). A bF message can be prevented by disabling the AlarmNet communicator. To prevent FC, remove any programming related to the panel's dialer. FC and bF can be prevented by disabling their respective programming fields.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |